Precision You Can Trust
NABL-Accredited Calibration | Available on Request
The Pico Technology CC057 service provides factory recalibration for an existing SOLT-AUTO-M or SOLT-AUTO-F electronic VNA calibration module. It applies to the TA518 SMA male and TA519 SMA female E-Cal standards. The returned module is recharacterised and its embedded traceable calibration data is updated for continued automated SOLT calibration through PicoVNA software. An RMA number is required before returning the module to Pico Technology..
The SOLT-AUTO-M or SOLT-AUTO-F Calibration Data Service, product code CC057, is intended for customers who already own a Pico Technology electronic calibration module and require renewed traceable calibration data.
The service applies to:
Each new Pico E-Cal standard is originally supplied with traceable calibration data stored within the module. CC057 is the factory recalibration option for updating that data on an existing male or female E-Cal module.
CC057 is a service, not a new calibration accessory.
The customer must already own a TA518 or TA519 module. The existing E-Cal must be returned to Pico Technology so that its electronic standards can be recharacterised.
The service does not include:
Pico states that it provides calibration only for its own SOLT, E-Cal and check standards.
| E-Cal Module | Order Code | RF Connector Configuration |
|---|---|---|
| SOLT-AUTO-M | TA518 | Two SMA male ports |
| SOLT-AUTO-F | TA519 | Two SMA female ports |
Both products are automated electronic two-port SOLT calibration modules designed for operation through PicoVNA software.
Unlike a manual SOLT kit, the TA518 and TA519 store their individual characterisation data inside the E-Cal hardware.
PicoVNA software uses this embedded information to:
CC057 updates the calibration data associated with the returned E-Cal module.
The applicable E-Cal modules electronically switch between:
These standards are used to calculate systematic VNA error corrections, including:
The CC057 service recalibrates the electronic standard module. It does not change the product into a different calibration type.
The service supports two connector configurations.
TA518 SOLT-AUTO-M
The TA518 has:
It is typically used where the VNA test cables or calibration reference planes terminate in SMA female connectors.
TA519 SOLT-AUTO-F
The TA519 has:
It is typically used where the VNA test cables or calibration reference planes terminate in SMA male connectors.
The TA518 and TA519 electronic calibration modules are characterised from 300 kHz to 8.5 GHz.
This supports calibration for measurements involving:
The frequency range describes the compatible E-Cal modules. CC057 itself is a recalibration service rather than a measurement device.
After recalibration, the TA518 or TA519 continues to use USB for:
The USB interface is a feature of the returned E-Cal hardware. CC057 does not include a separate USB-powered instrument unless Pico replaces the hardware under an agreed service arrangement.
The TA518 and TA519 use internal temperature stabilisation to improve repeatability during automated calibration.
Recalibration renews the characterised data for the returned module. Overall calibration quality still depends on:
The service should not be described as making every VNA measurement automatically error-free.
Pico states that new E-Cal SOLT standards are supplied with traceable calibration data embedded in the module. CC057 is the option to select when recalibration of an existing male or female E-Cal is required.
Traceable recalibration is relevant for:
A separate NABL calibration certificate should only be stated when RevineTech has confirmed that such a certificate is included and applies specifically to the returned module.
Pico requires an RMA number before the E-Cal standard is returned.
A typical return process includes:
Recalibration may be considered when:
The appropriate interval depends on usage, handling, connector condition and the organisation’s measurement assurance policy.
Recalibration updates the module’s characterisation, but it may not correct serious physical damage.
Before returning the module, inspect for:
Physical repair or replacement may require a separate assessment and quotation.
The recalibrated TA518 or TA519 can be used within supported PicoVNA calibration workflows, including setups based on:
The selected calibration sweep should remain within the E-Cal module’s characterised frequency range.
CC057 is suitable for E-Cal modules used in:
RevineTech can assist with the recalibration process for an existing TA518 or TA519 E-Cal module.
Support may include:
The final service quotation may include recalibration charges, freight, taxes and return logistics.
Applies to:
The recalibrated module continues to electronically switch between:
CC057 does not include:
| Service name | SOLT-AUTO-M or SOLT-AUTO-F Calibration Data |
| Pico product code | CC057 |
| Service type | Factory recalibration of an existing E-Cal SOLT standard |
| Applicable male module | TA518 SOLT-AUTO-M |
| Applicable female module | TA519 SOLT-AUTO-F |
| Existing E-Cal required | Yes |
| Return to Pico required | Yes |
| RMA required | Yes |
| New E-Cal included | No |
| Calibration data | Updated embedded traceable data |
| Calibration type | Automated electronic two-port SOLT |
| Supported manufacturer | Pico standards only |
| Specification | TA518 | TA519 |
|---|---|---|
| Pico type | SOLT-AUTO-M | SOLT-AUTO-F |
| RF ports | 2 | 2 |
| Connector gender | SMA male | SMA female |
| Nominal impedance | 50 Ω | 50 Ω |
| Standards | Short, open, load, through | Short, open, load, through |
| Operation | Automated electronic switching | Automated electronic switching |
| Power and control | USB | USB |
| Calibration data | Embedded | Embedded |
| Characterised range | 300 kHz to 8.5 GHz | 300 kHz to 8.5 GHz |