The PicoVNA Dual E-Cal TA520 is an automated two-port SOLT calibration kit containing separate SMA male and SMA female E-Cal modules. It covers 300 kHz to 8.5 GHz with 50 Ω interfaces and internally switched short, open, load and through standards. USB power and control, oven-stabilised operation and embedded traceable characterisation data support fast, repeatable PicoVNA calibration with fewer manual RF connections..
The PicoVNA Dual E-Cal 8.5 GHz Automated Calibration Kit is designed to simplify and improve two-port vector network analyser calibration.
The TA520 kit contains:
Together, the male and female E-Cal modules support calibration for a wider range of test cables, adaptors, fixtures and devices than a single connector configuration.
A conventional manual SOLT calibration normally requires the operator to connect several individual standards to each VNA port.
These operations may include:
Each additional connection introduces a possibility of:
The TA520 E-Cal kit reduces the process to a single RF connection for the selected male or female module. PicoVNA software then switches between the internal standards automatically and reads the module’s stored characterisation data over USB.
The TA520 is a dual kit containing two independent calibration modules.
| Module | Order Code | Connector Configuration |
|---|---|---|
| SOLT-AUTO-M | TA518 | Two SMA male ports |
| SOLT-AUTO-F | TA519 | Two SMA female ports |
The dual configuration is useful when the laboratory regularly measures devices or fixtures with different connector genders.
Typical measurement setups include:
The TA520 should not be described simply as one device with interchangeable male and female connectors. It is a kit containing two separately characterised E-Cal modules.
Both E-Cal modules are characterised from:
This frequency range covers the full measurement bandwidth of current PicoVNA instruments operating below 8.5 GHz and supports common RF applications involving:
The calibration frequency range should be presented as 300 kHz to 8.5 GHz, not simply 8.5 GHz.
Each E-Cal module contains electronically switched calibration states representing:
These standards allow PicoVNA software to calculate systematic measurement-error corrections for a two-port VNA setup.
SOLT calibration can correct errors associated with:
The correction is applied at the selected calibration reference planes so the displayed results more accurately represent the connected device under test.
Electronic standards cannot produce perfectly ideal open, short, load and through responses because internal switches, transmission paths and connectors introduce small imperfections.
Pico reduces their effect by characterising the complete RF behaviour of each module across the full operating frequency span.
The stored characterisation includes multipath S-parameter data for the internal states. PicoVNA software reads this data directly from the module through USB and uses it during calibration.
This approach compensates for the actual measured behaviour of the E-Cal module rather than treating every internal standard as mathematically ideal.
Each TA518 and TA519 module includes an internal oven system that stabilises the temperature of the RF calibration standards.
Published operating details include:
Temperature stabilisation helps reduce changes in the electrical response of the internal switches, transmission paths and standards.
This supports:
The module should be allowed to complete its warm-up process before calibration is started.
The E-Cal modules use a USB 2.0 Micro connection for:
A separate external power adaptor is not required for each E-Cal module.
The USB connection does not carry the RF measurement signal. RF measurements pass through the two SMA calibration ports, while USB manages the module’s control and stored reference data.
Pico Technology states that its VNA calibration and check standards are calibrated against fully traceable PC3.5 standards.
The E-Cal modules are supplied with their characterisation data embedded in internal memory, allowing PicoVNA software to identify the device and apply its individual calibration information automatically.
Traceable characterisation supports applications such as:
A separate NABL calibration certificate should be mentioned only if RevineTech confirms that it is included within its own commercial package. Pico’s official TA520 product page states traceability to PC3.5 standards but does not identify an NABL certificate as a standard manufacturer inclusion.
The individual TA518 and TA519 modules provide the following published calibration performance:
These specifications describe the residual calibration performance associated with the characterised E-Cal module under the stated operating conditions.
Measurement performance in a complete setup also depends on:
Each E-Cal module has published RF port limits of:
The protection rating should not be treated as a normal operating level.
Before calibration, the VNA source power should be checked to ensure that it remains within the specified operating limit.
A typical automated calibration process includes:
The E-Cal module automates the standards, but correct connector handling, cable positioning and reference-plane selection remain essential.
One of the principal benefits of E-Cal is the reduction in repeated connect and disconnect operations.
Fewer connections can help:
Automated calibration is particularly useful in environments where calibrations are repeated regularly or performed by several operators.
The PicoVNA Dual E-Cal Kit is suitable for:
The TA520 kit contains:
Each module internally switches between:
This reduces repeated manual connection of individual standards.
The complete characterised bandwidth supports low-frequency RF through microwave measurements.
USB provides:
The modules are characterised against traceable PC3.5 reference standards.
Each module measures approximately:
Pico Technology supplies its VNA calibration and check standards in a protective carrying case.
| Specification | PicoVNA Dual E-Cal TA520 |
|---|---|
| Product type | Dual automated electronic VNA calibration kit |
| Pico order code | TA520 |
| Included E-Cal modules | TA518 and TA519 |
| Calibration method | Two-port SOLT |
| Standards | Short, open, load and through |
| Frequency range | 300 kHz to 8.5 GHz |
| Nominal impedance | 50 Ω |
| Male module | TA518, two SMA male ports |
| Female module | TA519, two SMA female ports |
| Module control | USB 2.0 Micro |
| Power source | USB |
| Characterisation | Full multipath S-parameter data |
| Data storage | Embedded within each USB-controlled module |
| Temperature control | Internal oven |
| Software | PicoVNA software |
| Specification | TA518 SOLT-AUTO-M | TA519 SOLT-AUTO-F |
|---|---|---|
| Port count | 2 | 2 |
| Connector gender | SMA male | SMA female |
| Port impedance | 50 Ω | 50 Ω |
| Calibration standards | Short, open, load, through | Short, open, load, through |
| Frequency range | 300 kHz to 8.5 GHz | 300 kHz to 8.5 GHz |
| Characterisation data | Embedded | Embedded |
| Control and power | USB 2.0 Micro | USB 2.0 Micro |
| Temperature stabilisation | Oven controlled | Oven controlled |
| Parameter | Published Value |
|---|---|
| Directivity | 40 dB |
| Source match | 40 dB |
| Load match | 36 dB |
| Reflection tracking | 0.05 dB |
| Transmission tracking | 0.04 dB |
| Transfer calibration method | SOLT comparison |
The published values are specified for the individual TA518 and TA519 E-Cal modules.
| Specification | Value |
|---|---|
| Normal operating input | Up to +10 dBm |
| Protection limit | +20 dBm or 1 V peak |
| Port impedance | 50 Ω |
| RF connector | SMA male or SMA female, module-dependent |
| Specification | Details |
|---|---|
| Operating temperature | 5°C to 40°C |
| Oven-controlled range | 18°C to 28°C for quoted accuracy |
| Typical oven warm-up | 45 seconds at 23°C |
| Storage temperature | −20°C to 50°C |
| Operating humidity | 5% to 80% RH, non-condensing |
| Storage humidity | 5% to 80% RH, non-condensing |
| Specification | Details |
|---|---|
| Dimensions | 65 × 43 × 15 mm, including connectors |
| Weight | Approximately 60 g |
| Control connector | USB 2.0 Micro |
| RF ports | Two SMA connectors |
| Enclosure | Compact portable module |