The RIGOL MSO8000A Series is a high-performance mixed-signal digital oscilloscope designed for embedded-system debugging, signal-integrity testing, high-speed electronics, automotive systems, power analysis and R&D. It offers up to 3 GHz analog bandwidth, 10 GSa/s real-time sampling, 12-bit vertical resolution, 500 Mpts memory, 600,000 wfms/s capture and optional 16-channel digital analysis through a 10.1-inch capacitive touchscreen..

The RIGOL MSO8000A Series Mixed-Signal Digital Oscilloscope is designed for engineers, electronics manufacturers, research laboratories and industrial test teams that need high-bandwidth signal acquisition, deep memory and advanced waveform analysis in one instrument.
Built on RIGOL’s UltraVision II technology platform and proprietary ASIC architecture, the MSO8000A combines four analog channels, an external trigger input and optional 16-channel digital acquisition for time-correlated analog and digital debugging.
The series supports applications including:
The RIGOL MSO8000A Series includes:
All models provide:
The available bandwidth and sample rate can depend on the number of active channels. RIGOL specifies that lower-bandwidth models can be upgraded through software, with bandwidth up to 3 GHz available in supported single-channel operation.

The series provides analog bandwidth options from 750 MHz to 3 GHz, making it suitable for analysing fast clock signals, high-speed data interfaces, switching waveforms and communication systems.
Higher bandwidth supports detailed evaluation of:
The MSO8204A provides 2 GHz nominal bandwidth and can be upgraded to 3 GHz using the applicable software bandwidth option. Full 3 GHz operation is available under the supported channel configuration.
The MSO8000A provides a maximum real-time sampling rate of up to 10 GSa/s.
High sampling density helps preserve waveform detail during the acquisition of:
The maximum sampling rate is achieved in supported channel modes. When more analog channels are enabled, the sample rate available to each active channel may decrease.
The MSO8000A uses a 12-bit analog-to-digital conversion system, providing 4,096 discrete amplitude levels.
Compared with a conventional 8-bit oscilloscope, the 12-bit architecture provides 16 times more vertical quantisation levels.
This supports:
RIGOL identifies 12-bit resolution as a core capability of the current MSO8000A platform.

The series provides up to 500 Mpts memory depth.
Deep acquisition memory allows engineers to capture longer signal records while maintaining a useful sample rate.
This is particularly valuable for:
Full-memory hardware measurement allows the oscilloscope to calculate results using the complete acquired record rather than only the portion currently visible on the screen.

The MSO8000A supports waveform capture rates up to 600,000 waveforms per second.
A faster capture rate reduces acquisition dead time and increases the probability of detecting:
This capability improves debugging efficiency when the fault does not occur during every acquisition.

The hardware waveform recording function supports up to approximately 450,000 frames.
Segmented recording stores waveform events that meet the configured trigger conditions and records timing information for each captured frame.
Engineers can use waveform recording to:
RIGOL states that the MSO8000A combines 500 Mpts memory with up to 450,000 frames of hardware waveform recording.

The MSO8000A supports up to 16 digital channels with a compatible logic probe.
Mixed-signal acquisition allows engineers to view analog and digital activity on the same time-correlated display.
This is useful for:
The digital-channel capability requires the appropriate logic probe and may depend on the instrument configuration.
The optional eye diagram function provides a visual representation of digital signal quality.
Eye diagram measurements can help engineers evaluate:
Eye diagrams are useful during high-speed digital development and preliminary signal-integrity evaluation.
The eye diagram and advanced jitter functions require the applicable MSO8000-JITTER software option or an option bundle that includes these capabilities.
The optional jitter-analysis function can measure and statistically analyse multiple consecutive bits.
Available jitter workflows can include:
This functionality supports:
RIGOL identifies multi-bit statistical jitter analysis as a principal MSO8000A capability.
The series provides multiple trigger types for isolating specific waveform and protocol conditions.
Trigger functions include:
Advanced triggering allows engineers to capture specific faults instead of reviewing large numbers of normal waveform acquisitions.
The MSO8000A supports serial bus triggering and decoding for embedded, automotive, audio and aerospace applications.
Available protocol options include:
Protocol support depends on the installed software licence.
Decoded information is displayed alongside the electrical waveform, helping users identify:
The oscilloscope supports a broad range of waveform-analysis functions, including:
These tools allow engineers to move from waveform capture to fault identification without transferring every record to external analysis software.
The optional power-analysis package supports measurement of power electronic systems and switching devices.
Typical applications include:
Suitable high-voltage differential probes and current probes must be selected according to the voltage, current, bandwidth and common-mode requirements of the application.
The MSO8000A supports an optional built-in dual-channel arbitrary waveform generator.
The MSO8000-AWG option provides:
The generator can reduce the need for a separate function generator during routine laboratory testing.
The MSO8000A uses a 10.1-inch capacitive multi-touch display.
The touchscreen supports:
Physical knobs and buttons remain available for conventional oscilloscope operation.
Available connectivity includes:
These interfaces support:
SCPI command support allows the oscilloscope to be integrated into custom automated test systems.
Revine Tech supplies professional oscilloscopes, probes, software options and electronic test equipment for laboratory, industrial and research applications.
Our technical team can help customers select the appropriate configuration based on:
The final RIGOL MSO8000A price depends on the selected model, bandwidth upgrades, probes, software licences, accessories and calibration requirements.
The MSO8304A provides the highest bandwidth in the series at up to 3 GHz.
Lower-bandwidth models can be upgraded through software, subject to model and channel-mode limitations.
The 3 GHz bandwidth is available in supported single-channel operation.
The maximum 10 GSa/s sampling rate supports detailed acquisition of high-frequency and fast-transition signals.
The 12-bit ADC provides 4,096 vertical levels for improved small-signal and power-integrity measurements.
All MSO8000A models provide four analog channels plus one external trigger input.
This supports multi-rail, multi-phase and multi-signal measurements within one acquisition.
Up to 16 digital channels are available with a compatible optional logic probe.
Deep memory supports long acquisitions, detailed waveform zooming and full-record measurements.
The fast capture rate improves the probability of finding rare signal abnormalities.
Hardware segmented acquisition can record up to approximately 450,000 waveform frames.
Measurement results can be calculated from the full acquisition record instead of only the waveform currently displayed.
This is particularly useful for high-frequency, multi-cycle and long-memory measurements.
Optional eye diagram analysis supports preliminary evaluation of digital transmission quality and signal margins.
Optional jitter tools provide statistical, trend, histogram and spectrum-based timing analysis.
Available options support common embedded, automotive, audio and aerospace communication protocols.
Advanced trigger functions help isolate specific waveform conditions and low-probability faults.
The optional built-in waveform generator can provide circuit stimulation and test-signal generation directly from the oscilloscope.
Waveform histograms help engineers study amplitude and timing distributions across repeated acquisitions.
Mask testing supports repetitive waveform validation in production and reliability applications.
The large capacitive display provides a clear workspace for analog channels, digital channels, decoded buses, eye diagrams and measurement results.
The oscilloscope can be operated remotely through a compatible browser over a network connection.
Supported probe categories include:
Probe selection must match the required bandwidth, voltage range, current, common-mode voltage and input-loading limits.
| Model | Native Analog Bandwidth | Analog Channels | Digital Channels | Maximum Sample Rate | Maximum Memory |
|---|---|---|---|---|---|
| MSO8074A | 750 MHz | 4 + 1 EXT | 16 with optional logic probe | Up to 10 GSa/s | 500 Mpts |
| MSO8154A | 1.5 GHz | 4 + 1 EXT | 16 with optional logic probe | Up to 10 GSa/s | 500 Mpts |
| MSO8204A | 2 GHz | 4 + 1 EXT | 16 with optional logic probe | Up to 10 GSa/s | 500 Mpts |
| MSO8304A | Up to 3 GHz | 4 + 1 EXT | 16 with optional logic probe | Up to 10 GSa/s | 500 Mpts |
| Specification | Details |
| Product Series | RIGOL MSO8000A Series |
| Product Type | Mixed-Signal Digital Oscilloscope |
| Available Models | MSO8074A, MSO8154A, MSO8204A and MSO8304A |
| Analog Bandwidth | 750 MHz, 1.5 GHz, 2 GHz or 3 GHz |
| Analog Channels | Four |
| External Trigger | One EXT input |
| Digital Channels | Up to 16 with a compatible logic probe |
| Maximum Real-Time Sample Rate | Up to 10 GSa/s |
| Vertical Resolution | 12 bits |
| Vertical Quantisation Levels | 4,096 |
| Maximum Memory Depth | 500 Mpts |
| Maximum Waveform Capture Rate | Up to 600,000 wfms/s |
| Maximum Recording Frames | Up to approximately 450,000 |
| Display | 10.1-inch capacitive multi-touch display |
| Eye Diagram Analysis | Optional |
| Jitter Analysis | Optional |
| Power Analysis | Optional |
| Waveform Generator | Optional dual-channel, up to 25 MHz |
| Protocol Analysis | Option-dependent |
| Connectivity | USB Host, USB Device, LAN, HDMI, AUX and Web Control |
| Remote Programming | SCPI supported |
| Primary Applications | Embedded debugging, signal integrity, automotive electronics, power testing and R&D |
| Specification | MSO8204A |
| Native Analog Bandwidth | 2 GHz |
| Maximum Upgrade Bandwidth | 3 GHz in supported single-channel operation |
| Analog Channels | Four |
| External Trigger Input | One |
| Digital Channels | 16 with optional logic probe |
| Maximum Real-Time Sample Rate | 10 GSa/s |
| Vertical Resolution | 12 bits |
| Maximum Memory Depth | 500 Mpts |
| Maximum Waveform Capture Rate | 600,000 wfms/s |
| Maximum Hardware Recording | Approximately 450,000 frames |
| Display | 10.1-inch capacitive touchscreen |
| Optional AWG | Two channels, up to 25 MHz |
| Eye and Jitter Analysis | Optional |
| Function | Availability |
| Automatic Measurements | Supported |
| Full-Memory Measurements | Supported |
| Cursor Measurements | Supported |
| FFT Analysis | Supported |
| Waveform Mathematics | Supported |
| Measurement Statistics | Supported |
| Histogram Analysis | Supported |
| Mask Testing | Supported |
| Pass/Fail Testing | Supported |
| Hardware Recording and Playback | Supported |
| Search and Navigation | Supported |
| Eye Diagram | Optional |
| Jitter Analysis | Optional |
| Power Analysis | Optional |
| Trigger Category | Available Functions |
| Basic | Edge, pulse and video |
| Timing | Duration, timeout, delay and Nth edge |
| Signal Quality | Runt, slope and window |
| Digital | Pattern and setup/hold |
| Protocol | Serial bus triggering with applicable licence |
| Protocol Category | Supported Protocols |
| Embedded | I2C, SPI and RS232/UART |
| Automotive | CAN, LIN and FlexRay |
| Audio | I2S |
| Aerospace | MIL-STD-1553 |